get system information

racadm getsysinfo

reset drac

racadm racreset soft

racadm(Manage dell sever via ssh idrac)

List system events.

racadm getsel

How many event in log

racadm getsel -i

Read 7 event from line 10.

racadm getsel -s 10 -c 7

Read lifecycle log

racadm lclog view

Read lifecycle logs of warning critical version.

racadm lclog view -s Warning,Critical -n 5

Reset idrac

racadm racreset -f

Version of idrac

racadm getversion

Is sol enabled

racadm get iDRAC.IPMISOL

Login via sol/serial

racadm console com2

Short info about system

racadm getsysinfo

Long output inventory

hwinventory

View settings

racadm get BIOS.ProcSettings.ProcVirtualization

Set value

racadm set BIOS.ProcSettings.ProcVirtualization Disabled
[Key=BIOS.Setup.1-1#ProcSettings]
RAC1017: Successfully modified the object value and the change is in
       pending state.
       To apply modified value, create a configuration job and reboot
       the system. To create the commit and reboot jobs, use "jobqueue"
       command. For more information about the "jobqueue" command, see RACADM
       help.